Desco
Desco
  • Видео 114
  • Просмотров 375 004
Combo Tester X3+ - Product Overview | DESCO
The Desco Combo Tester X3+ verifies the functionality of personnel grounding devices (wrist straps, foot grounders, ESD shoes, smocks). Three independent tests are performed simultaneously on the wrist strap and each foot. Test prompts and test results with resistance measurements are displayed on the 7 inch color touchscreen display. The administrator menu in the tester’s software may be accessed for test limit preferences. Access control to an ESD Protected Area can be further enforced by using the relay terminal on the Combo Tester X3+ and connecting it to an electronic door lock or turnstile to grant access only to those who have passed their personal grounding device tests.
Click the ...
Просмотров: 82

Видео

EMIT - SmartLog Pro® 2 - Overview and Production
Просмотров 3324 месяца назад
The EMIT SmartLog Pro® 2 verifies the functionality of an operator’s wrist strap and footwear, logs the test results, and controls access to an ESD Protected Area. All operator test activity is logged into the SmartLog Pro® Manager Web App to meet the ANSI/ESD S20.20 requirements for an ESD Control Plan. The app is installed onto one server and accessed via a web browser. Each log entry include...
Chargebuster™ Plus Single-Fan Ionizer - Product Overview | DESCO
Просмотров 1455 месяцев назад
The Desco 60503 Chargebuster™ Plus Single-fan Ionizer is used for neutralizing electrostatic charges on insulators and ungrounded conductors. Its fast discharge times (less than 1 second at 12 inches) and ±10 volt offset voltage exceed the required limits of ANSI/ESD S20.20 and ESD TR53. The 60503 Chargebuster™ Plus Single-fan Ionizer monitors its offset voltage (balance), and it alarms when em...
What Is Wave Distortion Technology? | Desco
Просмотров 6466 месяцев назад
Desco Wave Distortion is the most reliable technology for the continuous monitoring of single-wire (conductor) wrist straps. “Wave Distortion” or vector impedance works by applying a continuous test voltage of 1.2 volts peak-to-peak at 1 to 2 microamperes (0.000002 amperes) to the wrist strap that is connected to the continuous or constant monitor. The test voltage creates a square wave that th...
Mini Monitor Installation Tutorial | DESCO
Просмотров 1,1 тыс.9 месяцев назад
The Desco Mini Monitor is the newest generation of ESD continuous monitor. It uses a unique illuminated enclosure to indicate the status of the operator and worksurface. Green indicates proper grounding of the operator and worksurface, red indicates a failure, and blue indicates when the operator port is vacant. Other new features include the ParkSnap™, mat monitor disablement, magnetic mountin...
Mini Monitor Product Tutorial | DESCO
Просмотров 1,1 тыс.9 месяцев назад
The Desco Mini Monitor is the newest generation of ESD continuous monitor. It uses a unique illuminated enclosure to indicate the status of the operator and worksurface. Green indicates proper grounding of the operator and worksurface, red indicates a failure, and blue indicates when the operator port is vacant. Other new features include the ParkSnap™, mat monitor disablement, magnetic mountin...
EMIT SmartLog Pro® 2 - Configuring the Proximity Reader
Просмотров 837Год назад
The EMIT SmartLog Pro® 2 verifies the functionality of an operator’s wrist strap and footwear, logs the test results, and controls access to an ESD Protected Area. All operator test activity is logged into the SmartLog Pro® Manager Web App to meet the ANSI/ESD S20.20 requirements for an ESD Control Plan. The app is installed onto one server and accessed via a web browser. Each log entry include...
Desco Combo Tester X3 & EMIT 50426 Limit Comparator - Calibration Tutorial
Просмотров 912Год назад
Frequency of re-calibration should be based on the critical nature of those ESD sensitive items handled and the risk of failure for the ESD protective equipment and materials. In general, EMIT recommends that calibration be performed annually. Use the EMIT 50426 Limit Comparator to perform periodic verification (once every 6-12 months) of the Desco Combo Tester X3 and EMIT SmartLog Pro® 2. The ...
Desco Pencil Ionizer - Installation Tutorial
Просмотров 466Год назад
The Desco Pencil Type Ionizer uses compressed clean dry air (CDA) to neutralize electrostatic charges and dislodge dust and debris in tight, compact spaces. It is an ideal choice when cleaning parts and assemblies in electronic, medical device, and semiconductor applications. It is commonly used in applications such as mobile phone manufacturing, PCB assembly, watch making, and the cleaning of ...
EMIT SmartLog Pro® 2 + Alvarado EDC Turnstile - Installation Tutorial
Просмотров 330Год назад
When paired with the EMIT SmartLog Pro® 2, the Alvarado EDC Waist High Turnstile controls access to the ESD Protected Area to operators that have passed their pre-defined ESD tests and have been granted access to the area. The Alvarado EDC turnstile is made of high-quality stainless steel and investment cast components. Designed to provide years of trouble-free operation, the turnstile rotates ...
EMIT ESD Glove Test Fixture - Product Tutorial with SmartLog Pro® 2
Просмотров 297Год назад
The EMIT 50755 Glove Test Fixture is designed to be used with the SmartLog Pro® 2 and Combo Tester X3 to test operators that wear ESD gloves or finger cots per Compliance Verification ESD TR53. The Test Fixture is made with a stainless steel electrode that creates a larger test surface area allowing the path-to-ground of the operator wearing gloves or finger cots to be measured. Click here to l...
EMIT Contactless Test Switch - Product Tutorial with SmartLog Pro® 2
Просмотров 170Год назад
The EMIT 50756 Contactless Test Switch is designed to be used with the SmartLog Pro® 2, Combo Tester X3, and Combo Tester X3 Plus to test operators that wear foot grounders or dual-wire wrist straps. An infrared sensor overrides the test switch on the personnel tester and allows operators to perform tests without contact. The contactless test switch will only work with dual-wire (conductor) wri...
Do Wireless Wrist Straps Actually Work? | Desco ESD Myths
Просмотров 12 тыс.Год назад
Do Wireless Wrist Straps Actually Work? | Desco ESD Myths
Desco Shock Cord Foot Grounder - Product Overview
Просмотров 478Год назад
Desco Shock Cord Foot Grounder - Product Overview
EMIT SmartLog Pro® 2 - Calibration Tutorial
Просмотров 915Год назад
EMIT SmartLog Pro® 2 - Calibration Tutorial
EMIT SmartLog Pro® 2 - Installation Overview
Просмотров 1,7 тыс.2 года назад
EMIT SmartLog Pro® 2 - Installation Overview
Desco 98133 AC Outlet Analyzer & Wrist Strap Tester | Product Overview
Просмотров 9552 года назад
Desco 98133 AC Outlet Analyzer & Wrist Strap Tester | Product Overview
Desco 19332 Light Tower
Просмотров 3092 года назад
Desco 19332 Light Tower
Desco Full-Time Continuous Monitor - Product Tutorial
Просмотров 9452 года назад
Desco Full-Time Continuous Monitor - Product Tutorial
Desco Full-Time Continuous Monitor - Installation Tutorial
Просмотров 1,8 тыс.2 года назад
Desco Full-Time Continuous Monitor - Installation Tutorial
SmartLog Pro® Manager - SmartLog Pro® SE Settings
Просмотров 4952 года назад
SmartLog Pro® Manager - SmartLog Pro® SE Settings
SmartLog Pro® Manager Software Upgrades
Просмотров 3692 года назад
SmartLog Pro® Manager Software Upgrades
Statguard Flooring - 46006 Body Voltage Meter
Просмотров 5132 года назад
Statguard Flooring - 46006 Body Voltage Meter
FreeStyle 8400™ Floor Installation Guide | Statguard Flooring
Просмотров 5462 года назад
FreeStyle 8400™ Floor Installation Guide | Statguard Flooring
Desco Dual Operator Continuous Monitor - Product Tutorial
Просмотров 5153 года назад
Desco Dual Operator Continuous Monitor - Product Tutorial
SmartLog Pro® Manager Scheduled Reports
Просмотров 2973 года назад
SmartLog Pro® Manager Scheduled Reports
SmartLog Pro® Manager User Setup
Просмотров 3283 года назад
SmartLog Pro® Manager User Setup
SmartLog Pro® Manager Alerts
Просмотров 2133 года назад
SmartLog Pro® Manager Alerts
Desco Dual Operator Continuous Monitor - Installation Overview
Просмотров 7123 года назад
Desco Dual Operator Continuous Monitor - Installation Overview
Trustat® 19550 Benchtop AC Ionizer - Product Overview
Просмотров 4213 года назад
Trustat® 19550 Benchtop AC Ionizer - Product Overview

Комментарии

  • @AK-oe6io
    @AK-oe6io Месяц назад

    Hello How to buy it ?

  • @conorbaird9409
    @conorbaird9409 2 месяца назад

    This was just the video I needed! Thank you Mr. Heckler

  • @lindavereycken7454
    @lindavereycken7454 3 месяца назад

    This is a great video !

  • @Jovanka_11061
    @Jovanka_11061 4 месяца назад

    Thank you for great video. I have 1 question, is it safe & proper for Soldering Company (SMT) have operator only wear sock (without ESD shoes) work in SMT Line? thank you

  • @ninjapwnsatlyfe
    @ninjapwnsatlyfe 5 месяцев назад

    awesome how the engineer heading my current machine build could not explain what a 2 minute video did just fine lol

  • @antoniomateos902
    @antoniomateos902 8 месяцев назад

    el valor para la RTG debe ser < 1.0 x10^9 ohms???

  • @dunesurfermt5004
    @dunesurfermt5004 10 месяцев назад

    Well done

  • @ClaudiaGarcia-r8e
    @ClaudiaGarcia-r8e Год назад

    Cuál es el voltaje que aplica el equipo para la medición del piso?

    • @DescoESDControl
      @DescoESDControl Год назад

      El medidor cambiará automáticamente su voltaje de prueba de 10 V a 100 V cuando la resistencia medida sea de 1 x 10⁶ ohmios o más para cumplir con el procedimiento de prueba descrito en ESD TR53.

  • @daphnejanssen6596
    @daphnejanssen6596 Год назад

    Hi, how do you measure the ground point itself?

  • @davidmcneil2296
    @davidmcneil2296 Год назад

    Still sounds like a bit of hogwash. I mean how is this used practically in our every day lives?

  • @ronthehealer
    @ronthehealer Год назад

    There are so many variables for this! If we eat low energy foods we omit lower frequency, same can be said what we drink. We also give away energy on a daily basis, toxic environment, energy vampires, pollution on the other hand their are so many ways to generate energy in the body, 1000's of years ago we were practicing such techniques, thats why they choose to hide the knowledge, but now its being revealed.

  • @yosoylagc
    @yosoylagc Год назад

    thanks

  • @Leon-nx4cz
    @Leon-nx4cz Год назад

    William reich,and larvahosky,both claimed a perfect young healy cell is 100mv, a healthy old person is 60mv, and a sick person with cancer is 15 to 20mv.they could cure people and reverse aging just by bringing the voltages back up to 100mv,they did that with the lahvasky multi wave oscillator.or the orgone accumulator,,any thoughts on this?

  • @zozoart
    @zozoart Год назад

    What is better? A copper needle or a stainless steel needle.

    • @DescoESDControl
      @DescoESDControl Год назад

      We do not have any data on copper emitters; however, stainless steel is inferior to tungsten. Tungsten emitters do not rust nor experience any other excessive degradation. This property makes them a popular choice for use in in ISO Class 1 or cleaner environments. All Desco ionizers use tungsten emitters.

  • @ColocasiaCorm
    @ColocasiaCorm Год назад

    How loud is it

  • @keithsherri9096
    @keithsherri9096 2 года назад

    Does the orientation of the mat matter? we have a mat that is blue on both sides and it is unclear what side should be up.

  • @anilmassey3135
    @anilmassey3135 2 года назад

    How many prizes

  • @ceemee331
    @ceemee331 2 года назад

    Do I need to use 2 strips of copper for this to work?. I have a 5×7 room to do this in.

    • @DescoESDControl
      @DescoESDControl 2 года назад

      Per our 8400 Series Vinyl Floor Tile Installation Instructions (TB-9032), Ground Strips should be installed prior to application of the conductive adhesive and tile, which will be applied directly on top of the copper strips. Identify the proper locations for the strips, typically along the base of walls or at columns where there is access to a grounding point (e.g., electrical outlet). Install one (1) ground strip for each 1,000 square feet of floor area, with a minimum of two (2) in any individual room.

  • @namikpashastudio
    @namikpashastudio 2 года назад

    thanks, sir.

  • @cytiuris.2915
    @cytiuris.2915 2 года назад

    They say grounding is good for health. So, should one stand on earth with a moist surface (wet earth) ? Won't the grounding be achieved if the surface is dry?

    • @DescoESDControl
      @DescoESDControl 2 года назад

      We specialize in making personnel ground products for ESD control for electronics assembly. We cannot make any claims as to the health benefits of grounding the human body.

  • @PoojaPooja-im4rn
    @PoojaPooja-im4rn 2 года назад

    Thank you so much sir …I have one doubt , when you are checking the ESD on Matt by SRM meter you are connected the electrodes (yellow colour object) to SRM ,I want to know y it is connected & purpose of connecting the electrode

    • @DescoESDControl
      @DescoESDControl 2 года назад

      The ESDA describes the design and use this type of electrode in the TR53-01-22 document. The TR53-01-22 is a complimentary downloaded at ESDA. You might also find useful information on the video of our surface resistance meter.

  • @alicihangir7222
    @alicihangir7222 2 года назад

    Don't you suppose to have Wristband attached to the ground via the mat.

  • @quetzaltechnologiesled9331
    @quetzaltechnologiesled9331 2 года назад

    if human body is electrostatic charge what is the body resistance?

    • @DescoESDControl
      @DescoESDControl 2 года назад

      The important thing to understand is the human body is a conductor (measured in ohms of resistance) and the electro-static charge is measured in volts. Because the human body is a conductor, a static charge can be induced onto it. An ungrounded body can then act as a capacitor to hold the charge.

  • @tze-ven
    @tze-ven 2 года назад

    Can electrostatic charges be removed from charged plastic by rubbing it on the ESD mat?

    • @DescoESDControl
      @DescoESDControl 2 года назад

      No. Plastics (unless specifically designed with conductive compounds) are insulators. Insulators must adhere to the 1 inch/12 inch requirement from ESD susceptible devices or ionization must be used to neutralize the charge on the insulator. Even if the plastic was conductive, rubbing it would be ineffective. Conductors must be continually grounded.

  • @samanthabloodsaw2944
    @samanthabloodsaw2944 3 года назад

    Teacher bus english or quick books I need

  • @samanthabloodsaw2944
    @samanthabloodsaw2944 3 года назад

    Ecomincs was in rose woods for hoilday

  • @Paulame99
    @Paulame99 3 года назад

    Very informative video, very well explained, many thanks to you sir 🙏

  • @peachycream8674
    @peachycream8674 3 года назад

    I’ve killed so many phones by holding them bare, electrical devices keep freezing or don’t work for me when I hold them for long but if someone else touches it, it magically works again. :( thanks for the info!!

    • @deanharrison7826
      @deanharrison7826 2 года назад

      Hi Get a wire and keep rounding yourself out to the ground

  • @realdragon13
    @realdragon13 3 года назад

    Hi Gregg, My name is Jeremy Suttie, I'm a Quality Manager for an In-flight Entertainment company and had a question about your Personal Safety slide, bullet three. You mention the "standard" outlines bullet three, "Grounding not recommended over 250 volts - energized equipment, HIPOT testing, etc.", but I am unable to find this information within the ANSI/ESD S20.20-2014 document. Is this the "standard" you're referring to or another? Appreciate the assistance!

  • @dullvoicereader
    @dullvoicereader 3 года назад

    Thanks for the clear and informative video!

  • @kennethloughrey3173
    @kennethloughrey3173 4 года назад

    I have one of the 19492 models and after zeroing it doesn't seem to work on anything even an statically charged balloon.

  • @mostoriautomationsolutions548
    @mostoriautomationsolutions548 4 года назад

    Wow! Great info thanks for sharing.

  • @mostoriautomationsolutions548
    @mostoriautomationsolutions548 4 года назад

    Very good Please follow our channel too, Thank you.

  • @BessieKaine
    @BessieKaine 4 года назад

    Thank you for this thorough explanation.

  • @seth5394
    @seth5394 4 года назад

    damn so we generate more volts than a car battery

  • @davidhernandez8980
    @davidhernandez8980 4 года назад

    Great info thanks for sharing Desco and Mr Gregg Heckler

  • @advancetech8781
    @advancetech8781 4 года назад

    Nice video ! electrostatic field meter ! www.advancetech.co.in/products/ssd-japan/static-charge-meter/dz4

  • @poppetrurazvan3900
    @poppetrurazvan3900 4 года назад

    Thank you very much guys!

  • @ulfpe
    @ulfpe 4 года назад

    Horrible music

  • @moneypenni1694
    @moneypenni1694 4 года назад

    so isn't a person 'grounded' when they go barefoot on the earth?

    • @DescoESDControl
      @DescoESDControl 4 года назад

      Technically you could be if the ground you were standing on was conductive enough. For instance, moist or wet earth, but not sand. You certainly would not want to be barefooted in a production environment, and you would have no safety resistance to protect you from electrical shock.

    • @moneypenni1694
      @moneypenni1694 4 года назад

      @@DescoESDControl ; Thank you. I was shocked pretty severely when I was a child, it knocked me out for 2 hours. I am very careful around electricity.....LOL!!

  • @charleslane2735
    @charleslane2735 4 года назад

    I was thinking about both a esd bench mat and floor,both with grounding snaps,but I was wondering,would it be safe to have both a heel grounding strap connected to the floor mat and connected to a hip to wrist strap?,also please note:I am planning on having four ground wires,two for the bench mat and two for the floor mat and connected to the same receptacle as the bench mat.

    • @DescoESDControl
      @DescoESDControl 4 года назад

      The best solution would be to keep each part of the your grounding system separate and not daisy chained together as suggested. If you were to connect your heel strap to your wrist strap which is then connected to the floor mat, the minute you lift your foot off the ground, you would become ungrounded while working at that particular workstation. I would keep them separated by having operators plug in their wrist strap while seated or wear their foot grounders while standing. • 09740 - Can be mounted under the workbench for operators to plug in their wrist straps. • Foot grounders are to be worn in combination with the floor mat. As long as the floor mat is grounded, then the person with foot grounders can stand or walk across the floor mat without accumulating a charge.

  • @charleslane2735
    @charleslane2735 4 года назад

    How do you wash these?

    • @DescoESDControl
      @DescoESDControl 4 года назад

      Statshield® smocks must be laundered periodically for proper operation. Desco recommends Woolite. Liquid detergents are better than dry because there is less caking and frictional wear. Use only non-ionic softeners and detergents when laundering. Launder Statshield® smocks in cool or warm water, tumble dry with low heat or hang dry. DO NOT USE BLEACH OR FABRIC SOFTENER. Launder Statshield® smocks by hand or with a washing machine. Use a standard household machine on gentle cycle or use an industrial machine if “Pony” (typically under 200 pound loads) machines are used. It is not recommended to launder these Statshield® smocks in heavy industrial laundry machines because it will lead to premature wear; degrading the ESD properties. Statshield® smocks should be tumbled dry using low heat. The carbon-suffused mono-filament nylon is sensitive to heat and should not be exposed to laundering heat in excess of 120°F. Under normal wearing and recommended washing conditions, Desco Statshield® ESD protective smocks will maintain their usefulness and effectiveness for a minimum of 100 washings.

  • @JorgeGarcia-vf1mz
    @JorgeGarcia-vf1mz 4 года назад

    Thank you Jim. It was a great presentation about grounding carts. One question, if you have epoxic floor or vinyl tile floor is the same behavior about the continuity between the floor and the wheels? Do you need special wheels when epoxic floor is used?

  • @brianhale2984
    @brianhale2984 4 года назад

    This video is very helpful!!

  • @charleslane2735
    @charleslane2735 4 года назад

    Are air ionizer safe to run while the worker or technician is in the room?

    • @DescoESDControl
      @DescoESDControl 4 года назад

      Operator safety always takes precedent to ESD control. Your facilities safety coordinator/officer should be consulted on any question of safety. Desco ionizers are intended to be used with an operator present. There are no known risks associated with using Desco ionizers.

    • @charleslane2735
      @charleslane2735 4 года назад

      @@DescoESDControl thank you

  • @BAZFANSHOTHITSClassicTunes
    @BAZFANSHOTHITSClassicTunes 4 года назад

    I just got an ionizer today and i can already feel the benefit. I can breath much easier.

    • @JamesZJi
      @JamesZJi 4 года назад

      hellow iron man

  • @charleslane2735
    @charleslane2735 4 года назад

    Is this to help with dust?

  • @theiriscen
    @theiriscen 4 года назад

    Thanks for the video. But shouldn’t you warn about being barefooted when wearing a grounding wristband ? I remember i got a shock when i was barefeet on tiles wearing my wristband but never got any shock when wearing it while laying on my bed. Being barefooted caused that or is it just me ?

    • @DescoESDControl
      @DescoESDControl 4 года назад

      If you were wearing a wrist strap and standing barefoot on conductive flooring of some type, you would only be protected from shock hazard up to 250 with the 1 megohm safety resistor in the strap cord. This would not be recommended even if you could go barefoot in a production environment.

    • @theiriscen
      @theiriscen 4 года назад

      @@DescoESDControl thank you

  • @savannahberd61
    @savannahberd61 5 лет назад

    Thanks for the video, I found it to be very interesting. What type are these? type C or Type D? I am trying to compare it to the bags from www.crohmiq.com/ I also am curious to know if you think size makes a difference? Thanks in advance